Created on Jul 11, 2023, 3:50 PM by Selina Luo/SANLIEN
Step 1. Check the link on address bar and look for "item=". In the example below "item=project_list"
http://wms.sanlien.com.tw/sanlien_crm/user.php?item=project_list
Step 2. Connect to wms via FTP and navigate to /var/www/html/sanlien_crm/user.php
Step 3. Look for the case "project_list" and ...
Read more...
|
Created on Jul 11, 2023, 3:56 PM by Selina Luo/SANLIEN
Step 1. Go to wms.sanlien.com.tw/sanlien
Step 2. Login with your credentials
Step 3 . Click on the device or project type (Palert Plus, VMS, Geo Tech) Step 4. Click the plus icon on the upper right corner to add new devices on the project Step 5. Edit the name and change the serial numbers Step ...
Read more...
|
Created on Jul 11, 2023, 4:49 PM by Selina Luo/SANLIEN
Step 1. Go to wms.sanlien.com.tw/sanlien_crm/ Step 2. Log in your account Step 3. Click on Palert Plus or the corresponding project name as shown in the picture below : Step 4. Select the site location on the right menu bar, eg : Napier Port Image Step 5. Select the device you are looking for the ...
Read more...
|
Created on Jul 11, 2023, 4:54 PM by Selina Luo/SANLIEN
Step 1. FTP connect to the station
Step 2. Navigate to /home/pi/Desktop/vAlert/bin/vAlert8.cfg
Step 3. Change serial_number with the serial number of the device and copy and paste the code below at the end of vAlert8.cfg # API [API_CONFIG] EARTHQUAKE_FALLING_API YES
DIN_FILE_UPLOAD YES ...
Read more...
|
Created on Jul 11, 2023, 4:56 PM by Selina Luo/SANLIEN
Step 1. FTP connect to the station. Step 2. Navigate to /home/pi/Desktop/vAlert/bin/vAlert8.cfg
Step 3. Change serial_number with the serial number of the device and copy and paste the code below at the end of vAlert8.cfg # API [API_CONFIG] EARTHQUAKE_FALLING_API YES
ISO2631_FILE_UPLOAD YES ...
Read more...
|
Created on Jul 11, 2023, 5:00 PM by Selina Luo/SANLIEN
Step 1. FTP connect to the station
Step 2. Navigate to /home/pi/Desktop/vAlert/bin/vAlert8.cfg
Step 3. Copy and paste the code below at the end of vAlert8.cfg # DORTS [DORTS_VIBRATION] BUILDING_TYPE 6
WARNING_DB -6
MAXIMUM_LATCH YES Step 4. Save and close
Step 5. Press 4 seconds on the device ...
Read more...
|
Created on Jul 11, 2023, 5:01 PM by Selina Luo/SANLIEN
Step 1. FTP connect to the station. Step 2. Navigate to /home/pi/Desktop/vAlert/bin/vAlert8.cfg
Step 3. Copy and paste the code below at the end of vAlert8.cfg # ISO2631 [ISO_2631] LOCATION_TYPE 2
MAXIMUM_LATCH YES Step 4. Save and close
Step 5. Press 4 seconds on the device start button to ...
Read more...
|
Created on Jul 11, 2023, 5:02 PM by Selina Luo/SANLIEN
Step 1. FTP connect to the station
Step 2. Navigate to /home/pi/Desktop/vAlert/bin/vAlert8.cfg
Step 3. Copy and paste the code below at the end of vAlert8.cfg # DIN [DIN_VIBRATION] FFT_SECONDS 10
DISPLAY_ON_LCD YES
STRUCTURE_TYPE 2
GEO_PHONE NO
RECORD YES
RECORD_ALWAYS YES
WARNING_DB -6
PGA_RELAY ...
Read more...
|
Created on Jul 11, 2023, 5:04 PM by Selina Luo/SANLIEN
ISO2631 is the international vibration standard which uses the vibration acceleration to set the standard. See the vibration table below:
Read more...
|
Created on Jul 11, 2023, 5:07 PM by Selina Luo/SANLIEN
DIN4150-3 is the German standard for vibration. DIN4150-3 is to regulate the vibration impact on structures, on X-axis we have the frequency and the Y-axis the Peak Per Velocity (PPV). Type 1 , Type2 , Type 3 are the types of structures with Type 1 being the least sensible to vibration and Type 3 ...
Read more...
|
Created on Jul 11, 2023, 5:17 PM by Selina Luo/SANLIEN
DORTS stands for Department Of Rapid Transit but is used on Palert plus to refer to the vibration standard used by the Department Of Rapid Transit in Taipei. The vibration velocity used in this standard comes from an integration of the acceleration generated by accelerometers in the device. See ...
Read more...
|
Created on Jul 11, 2023, 5:18 PM by Selina Luo/SANLIEN
1. Palert Plus Web interface has "DIN Daily" and "DIN EVENT" reports enabled in the left menu bar
2. Palert S3 web interface has "DORTS" and "ISO Daily" reports enabled in the left menu bar
3. PX-01 has none of the report above enabled on its menu bar
Read more...
|
Created on Jul 11, 2023, 5:20 PM by Selina Luo/SANLIEN
Step 1. FTP connect to station
Step 2. Navigate to /var/www/html/php/version.txt
Step 3. Change "Palert Plus" to "Palert Plus S3" or "Px-01"
Step 4. Save and refresh your web page
Read more...
|
Created on Jul 11, 2023, 5:21 PM by Selina Luo/SANLIEN
Step 1. FTP connect to station
Step 2. Navigate to /home/pi/Desktop/vAlert/bin/vAlert8.cfg
Step 3. Edit vAlert8.cfg , change "PD_TRIG_ENABLE NO" to "PD_TRIG_ENABLE YES"
Step 4. Save and press 4 seconds on Palert plus/Palert S3 start button to reload
Read more...
|
Created on Jul 11, 2023, 5:22 PM by Selina Luo/SANLIEN
Step 1. Use Putty to SSH connect to the station
Step 2. Type the command '$ df -h' and check the available storage
Step 3. If the available storage is 0 (which is most likely the case here), delete some files. If not, please contact TOM or TING for assistance.
Read more...
|
Created on Jul 11, 2023, 5:24 PM by Selina Luo/SANLIEN
Step 1. Open Putty
Step 2. SSH connect to station
Step 3. Type the command $ killall node
If command returns no process named node, type the command "$ node" and enter
If the command above returns "node:command not found", type the command "$ sudo apt-get install node"
Step 4. Refresh web ...
Read more...
|
Created on Jul 11, 2023, 5:26 PM by Selina Luo/SANLIEN
Step 1. Open Putty
Step 2. SSH connect to station
Step 3. Navigate to /etc/php5/apache2/php.ini.
Step 4. Edit the file php.ini at the short_ open_tag=Off and Change "Off " to "ON". Step 5. Save .
Step 6. Reload web page
Read more...
|
Created on Jul 12, 2023, 8:35 AM by Selina Luo/SANLIEN
Purpose of project
Send ftp files and to a remote ftp server and resend them in case of connection faillure. Note
ftp.sh is only sending the files modified in less than one hour . Manual Usage
Install FTP server on the Raspberry pi by running the command $ sudo apt-get update then $ sudo apt-get ...
Read more...
|
Created on Jul 12, 2023, 8:38 AM by Selina Luo/SANLIEN
In this short guideline i'm assuming that you know how to: - Use a FTP client (WinSCP)
- Set up a Palert station (Power and Ethernet)
- Git command line
Steps to upgrade to web interface: 1. Download the latest version
- Git : $ git clone http://gitlab.sanlien.com.tw/jean/palert-s3-web.git
- Or ...
Read more...
|
|